Ventilator
December 28, 2021 2022-01-05 13:08Ventilator
Ventilator
MH-GE Engstrom Carestation™ Verntilator
Description
Integrated ventilation and monitoring Plug and play modules provide advanced monitoring parameters Familiar user interface Adaptable and flexible to your environment Advanced aerosolized medication delivery with the Aerogen Customizable screens Non.invasive ventilation Easy to maintain Focused on patient safety
Volume Controlled (VCV) Pressure Controlled (PCV) Pressure Controlled, Volume Guaranteed (PCV •VG) Synchronized Intermittent Mandatory Ventilation Volume Controlled Synchronized Intermittent Mandatory Ventilation, Pressure Controlled ISIMV.PC) Synchronized Intermittent Mandatory Ventilation, Pressure Controlled, Volume Guaranteed (SIMV.PCVGI (optional) BiLevel Airway Pressure Ventilation (APRV capable) 8iLevel with Volume Guaranteed (BiLevel•VG) (optionall Non•lnuasive Ventilation INIV) (optional); nCPAP available with Neonatal option Constant Positive Airway PressureyPressure SupportVentilation ICPAPIPSVI Apnea backup available in SIMV•VC, SIMV•PC, BiLevel, SIMV.PCVG, BiLeueI.VG, CPAPjpsv and VG.ps (institutionally selectable defaults) Volume Guarantee Pressure Support IVG•PS) available with Neonatal option
Integrated ventilation and monitoring Plug and play modules provide advanced monitoring parameters Familiar user interface Adaptable and flexible to your environment Advanced aerosolized medication delivery with the Aerogen Customizable screens Non.invasive ventilation Easy to maintain Focused on patient safety
Volume Controlled (VCV) Pressure Controlled (PCV) Pressure Controlled, Volume Guaranteed (PCV •VG) Synchronized Intermittent Mandatory Ventilation Volume Controlled Synchronized Intermittent Mandatory Ventilation, Pressure Controlled ISIMV.PC) Synchronized Intermittent Mandatory Ventilation, Pressure Controlled, Volume Guaranteed (SIMV.PCVGI (optional) BiLevel Airway Pressure Ventilation (APRV capable) 8iLevel with Volume Guaranteed (BiLevel•VG) (optionall Non•lnuasive Ventilation INIV) (optional); nCPAP available with Neonatal option Constant Positive Airway PressureyPressure SupportVentilation ICPAPIPSVI Apnea backup available in SIMV•VC, SIMV•PC, BiLevel, SIMV.PCVG, BiLeueI.VG, CPAPjpsv and VG.ps (institutionally selectable defaults) Volume Guarantee Pressure Support IVG•PS) available with Neonatal option
MH-GE Ivent 201™ Ventilator
Description
Use Adaptive Flow’ & Adaptive l.Time• to enhance your patient’s comfort & reduce Work Of Breathing, by allowing the patient to manage their own inspiratory time & inspiratory flow rate in a volume targeted mode. Use our friendly Easy Exhale • feature to minimize problems of gas trapping, auto•peep & triggering failure in patients with acute obstructive lung disease. Adaptive Bi.Level• feature that enables a responsive and compensated ventilation. Adaptive Flow’ & Adaptive l•Time• for enhanced comfort and reduced WOB. 72 hour trending of all settings and monitored patient data, loops with freeze and overlay capability Waveform display providing visual feedback on patient condition. Respiratory mechanics (static and dynamic) Programmable nebulizer Built•in oxygen blender for precise oxygen delivery
Use Adaptive Flow’ & Adaptive l.Time• to enhance your patient’s comfort & reduce Work Of Breathing, by allowing the patient to manage their own inspiratory time & inspiratory flow rate in a volume targeted mode. Use our friendly Easy Exhale • feature to minimize problems of gas trapping, auto•peep & triggering failure in patients with acute obstructive lung disease. Adaptive Bi.Level• feature that enables a responsive and compensated ventilation. Adaptive Flow’ & Adaptive l•Time• for enhanced comfort and reduced WOB. 72 hour trending of all settings and monitored patient data, loops with freeze and overlay capability Waveform display providing visual feedback on patient condition. Respiratory mechanics (static and dynamic) Programmable nebulizer Built•in oxygen blender for precise oxygen delivery
MH-Vela Comprehensive™ Vantilator
Description
The AVEAE ventilator provides comprehensive critical care ventilation for the smallest patients in the NICU to children and adults with complex respiratory diseases. As an integral part of the CareFusion ventilation system solution, the AVEA ventilator not only meets your most demanding clinical needs with features such as invasive and noninvasive ventilation for all patients types, volumetric capnography and Esophageal Pressure Monitoring, but also brings actionable information to help better address clinical and operational challenges inpatient care.
The AVEAE ventilator provides comprehensive critical care ventilation for the smallest patients in the NICU to children and adults with complex respiratory diseases. As an integral part of the CareFusion ventilation system solution, the AVEA ventilator not only meets your most demanding clinical needs with features such as invasive and noninvasive ventilation for all patients types, volumetric capnography and Esophageal Pressure Monitoring, but also brings actionable information to help better address clinical and operational challenges inpatient care.
MH-Vela Avea™ Vantilator
Description
Viasys Carefusion Vela Ventilator. The Vela ventilator from Care Fusion has a precision servo controlled gas delivery turbine and active exhalation that gives you the performance you need to treat all of your pediatric and adult patients. Its flat panel, color LCD and touch screen provide flexibility with simplified controls to @rove safety. The Vela ventilator is a full function conventional ventilator and noninvasive positive pressure ventilator (NPPV) that provides you with the tools to support your patients throughout the continuum of care. The three models of the Vela ventilator come with a wide range of features for the critical care environment, allowing you to tailor it to your specific needs. Simple software upgrades allow optional features to be added at the time of purchase or ata later date.
Viasys Carefusion Vela Ventilator. The Vela ventilator from Care Fusion has a precision servo controlled gas delivery turbine and active exhalation that gives you the performance you need to treat all of your pediatric and adult patients. Its flat panel, color LCD and touch screen provide flexibility with simplified controls to @rove safety. The Vela ventilator is a full function conventional ventilator and noninvasive positive pressure ventilator (NPPV) that provides you with the tools to support your patients throughout the continuum of care. The three models of the Vela ventilator come with a wide range of features for the critical care environment, allowing you to tailor it to your specific needs. Simple software upgrades allow optional features to be added at the time of purchase or ata later date.
MH-Drager Babylog 8000+™Ventilator
Description
The Dräger Babylog 8000 plus is a microprocessor controlled time•cycled, pressure limited ventilator. A serial output allows for connection to an external PC that can display waveforms,control settings, and monitored parameters.lntended patient population : premature, newborn and infants up to 20 kg (45 lbsJ.The Babylog is the ventilator of choice for this population.
The Dräger Babylog 8000 plus is a microprocessor controlled time•cycled, pressure limited ventilator. A serial output allows for connection to an external PC that can display waveforms,control settings, and monitored parameters.lntended patient population : premature, newborn and infants up to 20 kg (45 lbsJ.The Babylog is the ventilator of choice for this population.
MH-Drager Savina™Ventilator
Description
Helps minimize risk to the patient Adapts to altering needs with ease Can support weaning Promotes long•term ventilation and recovery With its open breathing system, the Savina enables spontaneous breathing at any time and any pressure level in all ventilation modes during ventilation cycles. Features an internal turbine that removes the need for air cylinders or an external compressor Navigate power failures and support mobility with an internal battery Multiple ventilation modes accommodate various acuity levels and patient populations
Helps minimize risk to the patient Adapts to altering needs with ease Can support weaning Promotes long•term ventilation and recovery With its open breathing system, the Savina enables spontaneous breathing at any time and any pressure level in all ventilation modes during ventilation cycles. Features an internal turbine that removes the need for air cylinders or an external compressor Navigate power failures and support mobility with an internal battery Multiple ventilation modes accommodate various acuity levels and patient populations
MH-Drager Evita XL™Ventilator
Description
Versatile unit responds quickly to individual patient requirements and changing ventilation situations. Mask ventilation with NIV plus available in all modes with comprehensive monitoring and alarm adaptation. Integrated C02 monitoring helps verify correct intubation and metabolic stability. Lung protection package offers low flow PIV maneuver to identify optimal, PEEP and pressure settings for h’ng protective ventilation. Open breathing system with AutoFlowE or PCV* allows spontaneous breathing in all ventilation modes. Workflow support functions streamline clinical routines. NeoFlow offers flow measurement at the Y.piece for fast response to patient triggering, leakage adaptation, and precise volume delivery for neonates. SmartCare@ PS automated weaning system provides continuous vigilance for opportunities to reduce thelevelof ventilator support Automatic tube compensation supports respiratory independence during weaning process. Open breathing system with Mandatory Minute Ventilation ensures that patients, from neonates to adults, will receive the set minute volume, regardless of the spontaneous breathing level. Maneuverable trolley for movement throughout care facility.
Versatile unit responds quickly to individual patient requirements and changing ventilation situations. Mask ventilation with NIV plus available in all modes with comprehensive monitoring and alarm adaptation. Integrated C02 monitoring helps verify correct intubation and metabolic stability. Lung protection package offers low flow PIV maneuver to identify optimal, PEEP and pressure settings for h’ng protective ventilation. Open breathing system with AutoFlowE or PCV* allows spontaneous breathing in all ventilation modes. Workflow support functions streamline clinical routines. NeoFlow offers flow measurement at the Y.piece for fast response to patient triggering, leakage adaptation, and precise volume delivery for neonates. SmartCare@ PS automated weaning system provides continuous vigilance for opportunities to reduce thelevelof ventilator support Automatic tube compensation supports respiratory independence during weaning process. Open breathing system with Mandatory Minute Ventilation ensures that patients, from neonates to adults, will receive the set minute volume, regardless of the spontaneous breathing level. Maneuverable trolley for movement throughout care facility.
MH-Drager Evita-2 Dura™Ventilator
Description
The functional touch screen continually provides the clinician nformation on ventilator settings, patient measurements and advanced trending capabilities which enhances the operation of he device. Unique features and modalities such as AutoFIoww and APRV are standard on all Evita 4 ventilators. Neonatal, pediatric, adult – Evita 4 can be used to ventilate any patient category, reducing the amount of staff training required and ensuring greater resource flexibility. NeoFlow’M, offers flow measurement at the Y-piece for precise volume and leak monitoring with accurate, responsive triggering to patient effort.
The functional touch screen continually provides the clinician nformation on ventilator settings, patient measurements and advanced trending capabilities which enhances the operation of he device. Unique features and modalities such as AutoFIoww and APRV are standard on all Evita 4 ventilators. Neonatal, pediatric, adult – Evita 4 can be used to ventilate any patient category, reducing the amount of staff training required and ensuring greater resource flexibility. NeoFlow’M, offers flow measurement at the Y-piece for precise volume and leak monitoring with accurate, responsive triggering to patient effort.
MH-Drager Evita-4™Ventilator
Description
The functional touch screen continually provides the clinician nformation on ventilator settings, patient measurements and advanced trending capabilities which enhances the operation of he device. Unique features and modalities such as AutoFIoww and APRV are standard on all Evita 4 ventilators. Neonatal, pediatric, adult – Evita 4 can be used to ventilate any patient category, reducing the amount of staff training required and ensuring greater resource flexibility. NeoFlow’M, offers flow measurement at the Y-piece for precise volume and leak monitoring with accurate, responsive triggering to patient effort.
The functional touch screen continually provides the clinician nformation on ventilator settings, patient measurements and advanced trending capabilities which enhances the operation of he device. Unique features and modalities such as AutoFIoww and APRV are standard on all Evita 4 ventilators. Neonatal, pediatric, adult – Evita 4 can be used to ventilate any patient category, reducing the amount of staff training required and ensuring greater resource flexibility. NeoFlow’M, offers flow measurement at the Y-piece for precise volume and leak monitoring with accurate, responsive triggering to patient effort.
MH-Maquet-Servo-I™Ventilator
Description
For adult and pediatric patients. A ventilator system designed to operate in a variety of hospital. ventilatory care settings. Alarm output connector for external alarm (optional). Supports invasive ventilation and the option non-invasive. Ventilation (NIV) with leakage compensation. High level of sensitivity to your patient´s efforts. Precise gas delivery system. Extreme speed in sensing and regulation. Diagnostic trend tools ensure accurate time and detail recording. for up to 24 hours after an event. Volume/Pressure and Flow/Volume loops
For adult and pediatric patients. A ventilator system designed to operate in a variety of hospital. ventilatory care settings. Alarm output connector for external alarm (optional). Supports invasive ventilation and the option non-invasive. Ventilation (NIV) with leakage compensation. High level of sensitivity to your patient´s efforts. Precise gas delivery system. Extreme speed in sensing and regulation. Diagnostic trend tools ensure accurate time and detail recording. for up to 24 hours after an event. Volume/Pressure and Flow/Volume loops